CFR330/FXN525 Conventional Rate of Rise Heat Detector
£15.74
Eaton has a large range of detectors for conventional fire alarm systems designed to meet the demands of nearly any application. In the range, there are two main options either the flexible, easily switchable 5 in 1 detector that brings together all the detection mode or the straightforward single detection mode range. Both options include optical, photo-thermal and heat modes.
The most popular is the optical detector mode which is suitable for most commercial building application, giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.
The photo-thermal detector type responds quickly to fast, clean burning fires. They maintain an advantage over optical sensors when detecting smouldering fires which give rise to large visible smoke particles. The thermal enhancement of this detector allows a higher alarm threshold which provides greater rejection of false alarms. The detector will also raise an alarm at temperatures exceeding 60ºC. The heat detector option can be set in one of three sensing modes. Two fixed heat modes of 77oC or 92 oC and a rate of rise function which detects a rapid rise in temperature.
TECHNICAL SPECIFICATIONS
Detectors: |
FXN922 |
EFXN533 |
EFXN632 |
EFXN524 |
EFXN525 |
EFXN526 |
Description: |
5 in 1 multi-mode detector |
Optical Detector |
Photo-thermal detector |
Fixed heat detector (77ºC) |
Rate of rise detector |
Fixed heat detector (92ºC) |
Standards: |
EN54 Pt 5 & 7 2001 |
EN54 Pt7:2000 + A1: 2002 |
EN54 Pt 5 & Pt 7 2000, A1: 2002 |
EN54 Pt 5 2000, A1: 2002 |
||
Area Coverage: |
100m² (subject to local standards) |
100m² (subject to local standards) |
100m² (subject to local standards) |
50m² (subject to local standards) |
50m² (subject to local standards) |
50m² (subject to local standards) |
Start-up Current: |
340μA (max) |
N/A |
N/A |
340μA (max) |
340μA (max) |
N/A |
Heat Class: |
N/A |
N/A |
A2S |
BS |
A2R |
CS |
Alarm Temperature: |
N/A |
N/A |
60ºC |
77ºC |
60ºC |
92ºC |
Operating Temperature: |
-20ºC to 60ºC |
-20ºC to 60ºC |
-20ºC to 60ºC |
-20ºC to 60ºC |
-20ºC to 45ºC |
-20ºC to 75ºC |
Dimensions Excl Base (Dia x H): |
104mm x 42mm |
101mm x 33mm |
101mm x 33mm |
101mm x 43mm |
101mm x 43mm |
101mm x 43mm |
Dimensions Incl Base (Dia x H): |
104mm x 55mm |
101mm x 45mm |
101mm x 55mm |
101mm x 55mm |
101mm x 55mm |
101mm x 55mm |
Detection Mode: |
5 in 1 Multi-Mode |
Light Scatter Principle |
Light scatter principle & Heat sensitive element |
Heat sensitive element |
||
Operating Voltage: |
15V - 30Vdc |
|||||
Standby Current: |
30μA (max) |
|||||
Alarm Current: |
25mA (max) |
|||||
Mounting Position: |
Ceiling in open areas |
|||||
Mounting Options: |
Surface mount with standard base |
|||||
System Wiring: |
2 Core |
|||||
Indication: |
360º visible LED |
|||||
Humidity (Non-condensing): |
0 to 93% RH |
|||||
Construction: |
PC/ABS |
|||||
Colour: |
White |
|||||
Ingress Protection: |
IP40 |
|||||
EMC: |
CE Marked |
|||||
Suitable for use with: |
Eaton conventional fire systems |
|||||
|
|
|
|
|
|
|
Bases: |
EFXN520 |
|
|
|
|
|
Description: |
Standard Base |
|
|
|
|
|
Construction: |
PC / ABS |
|
|
|
|
|
Colour: |
White |
|
|
|
Shipping Weight: 100gms
|